Title :室内気流分布を考慮した通風性能評価に関する研究 : 室内通風デグリアワーを用いた戸建住宅の通風性能評価
Title alternative :STUDY ON THE EVALUATION OF CROSS VENTILATION PERFORMANCE CONSIDERING DISTRIBUTION OF INDOOR AIRFLOW VELOCITY : Evaluation of cross ventilation performance of the detached house with cross ventilation degree hours of inside area
Authors :赤林, 伸一
坂口, 淳
細野, 淳美
佐藤, 英樹
久保, 俊輔
Publisher :日本建築学会
Issue Date :Nov-2008
Journal Title :日本建築学会環境系論文集
Volume :73
Issue :633
Start Page :1261
End Page :1266
ISSN :1348-0685
Abstract :The distribution of indoor airflow velocity by cross ventilation is influenced by the regional climate conditions, and the location as well as the shape of the building. In this study, CVDHI_B, CVDHI_P and CVDHI_T of Cross Ventilation Degree Hours of Inside Area (CVDHI) are proposed. The CVDHI values of 2 cases to change the number and position of openings at 2 cities (Tokyo and Niigata) in Japan are calculated for the AIJ detached house model.The results are as follows; (1) The ratio of averaged CVDHI_P and CVDHI_B values is about 1:20 in Tokyo and Niigata. (2) The CVDHI values increases when an opening is placed on an opposite wall in a straight line, and placed at the corner of the room.
Keywords :Cross ventilation
Cross ventilation performance
SET*
Cross Ventilation Degree of Inside Area
通風
通風性能
室内通風デグリアワー
Type Local :学術雑誌論文
Language :jpn
Format :application/pdf
URI :http://hdl.handle.net/10191/18279
fullTextURL :http://dspace.lib.niigata-u.ac.jp/dspace/bitstream/10191/18279/1/ZF_633_1261-1266.pdf
Rights :社団法人日本建築学会
Appears in Collections:10 査読済論文 = Postprint

Please use this identifier to cite or link to this item: http://hdl.handle.net/10191/18279