タイトル :The development and assessment of program for volume measurement for CT images of DICOM data running on a personal computer (Development and assessment of volume measurement program for DICOM on PC)
著者 :Takahashi, Naoya
Kobayashi, Arashi
Nishihama, Saori
Minamizawa, Natsuki
Suzuki, Noriko
Higuchi, Takeshi
Ohkubo, Masaki
Narita, Akihiro
Sasamoto, Ryuta
公開者・出版者 :新潟大学医学部保健学科
刊行年月 :2017-3
掲載誌名 :新潟大学保健学雑誌
巻 :14
号 :1
開始ページ :27
終了ページ :33
ISSN :2188-4617
抄録 :Purpose: Volume estimation of organs or fluid is one of the most important roles in autopsy. The aim of this study is to develop a volume estimation program for CT images of Digital Imaging and Communication in Medicine (DICOM) which runs on a personal computer, and to confirm the usefulness and accuracy of it. Materials and methods: We developed a program which extracted correct boundaries of the organs in spite of setting of rough region of interest (ROI). We retrospectively evaluated five postmortem CT (PMCT) examinations which were performed with a 64-row detector CT. Volume of five livers, five spleens, and 10 kidneys were evaluated by means of a general image processing program and our developed program. The averages of obtained volume and required time to set ROIs were analyzed with paired t-test.Results: There were no significant differences for the estimated volume of all organs between with the general image processing program and with our program. However, there were significant differences for the required time to set ROIs between with the two methods in all organs. The mean evaluation time was shortened by 52.0%, 67.2% and 74.0% in liver, spleen, and kidney, respectively. Conclusion: Our developed program provided correct volume value, and was able to reduce labor and time to set ROIs compared with using the general image processing program. Our program is useful to evaluate the volume on CT images of DICOM data especially in PMCT.
キーワード :Computed tomography
Postmortem imaging
Autopsy imaging
DICOM
Organ volume
資料種別 :紀要論文
言語 :eng
フォーマット :application/pdf
URI :http://hdl.handle.net/10191/47194
fullTextURL :http://dspace.lib.niigata-u.ac.jp/dspace/bitstream/10191/47194/1/14(1)_27-33.pdf
出現コレクション:01 新潟大学保健学雑誌 = Journal of health sciences of Niigata University

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10191/47194

・学術リポジトリに登録されている研究成果の著作権は,著者,出版社(学協会)などが有します。

・学術雑誌に掲載された論文等は,発行された誌面とはレイアウトの相違や文言の違いなどがあり得ます。

・表示・ダウンロードした研究成果は,著作権法に規定されている私的使用,引用等の範囲内で利用してください。