ホーム    Nuar 総合案内    マイ・リポジトリ        English    ご意見

新潟大学学術リポジトリ Nuar >
090 医学部保健学科 = School of Health Sciences, Faculty of Medicine  >
10 学術雑誌論文 = Journal Article >
10 査読済論文 = Postprint >

 

登録ファイル

ファイル 記述 サイズフォーマット
jrst_59_12_1555_1560_2003.pdf77KbAdobe PDF
タイトル :Elliptical Centric法を用いた造影三次元MR Angiographyにおける造影効果持続時間および撮像タイミングに関する検討
別言語のタイトル :Duration of Enhancement and Scan Timing in Three-dimensional Contrast-enhanced MR Angiography Using the Elliptical Centric Phase-encoding Technique
著者 :八木下, 裕子
大越, 幸和
大久保, 真樹
内藤, 健一
井上, 智子
蔡, 篤儀
公開者・出版者 :日本放射線技術学会
刊行年月 :2003-12
掲載誌名 :日本放射線技術学会雑誌
巻 :59
号 :12
開始ページ :1555
終了ページ :1560
ISSN :0369-4305
内容記述 :In the present study, we quantitatively investigated the relationship between the signal intensity in a vessel and the duration of contrast enhancement as well as scan timing in 3D contrast-enhanced MR angiography using an elliptical centric phase-encoding technique. A tube phantom filled with Gd-DTPA, acting as a vessel, was taken out from the field of view during data acquisition, by using the “pause” function of our MR scanne(r GE Signa, 1.5 Tesla), thereby simulating the presence and absence of a vessel. The shortening of the duration of enhancement corresponds to the delay of scan timing from the optimal point in the phase-encoding of the centric-ordering system. The signal intensity in a vesse(l 1-5 mm in diameter)decreased as the duration of enhancement became shorter and the diameter of the vessel decreased. When the number of partitions was 16 or 32 in a 128-mm-thick slab, the signal intensity obtained by the elliptical centric phase-encoding technique was almost the same as that obtained by the conventional centric phase-encoding technique. However, when the number of partitions was increased(64-124), and if the duration of enhancement was short, the signal intensity obtained by the elliptical centric phase-encoding technique was higher than that obtained by the conventional centric phase-encoding technique. In conclusion, in terms of the duration of enhancement and the delay of scan timing, the elliptical centric phase-encoding technique is superior to the conventional centric phase-encoding technique when the number of partitions in a slab for 3D MR angiography is increased.
キーワード :Magnetic resonance angiography(MRA)
Three-dimensional contrast enhanced magnetic resonance angiography(3D-CE MRA)
Elliptical centric phase encoding
Centric phase encoding
Phase-encding order
資料種別 :学術雑誌論文
言語 :jpn
URI :http://hdl.handle.net/10191/4865
fullTextURL :http://dspace.lib.niigata-u.ac.jp/dspace/bitstream/10191/4865/1/jrst_59_12_1555_1560_2003.pdf
出現コレクション:10 査読済論文 = Postprint

このアイテムの引用には次の識別子を使用してください: http://hdl.handle.net/10191/4865

・学術リポジトリに登録されている研究成果の著作権は,著者,出版社(学協会)などが有します。

・学術雑誌に掲載された論文等は,発行された誌面とはレイアウトの相違や文言の違いなどがあり得ます。

・表示・ダウンロードした研究成果は,著作権法に規定されている私的使用,引用等の範囲内で利用してください。